Centrifuge External Influence Factors

A - Dosing device operation adjustment
The dosing device and centrifuge run interlock, and the continuity of dosing device directly affects the continuous operation of centrifuge. The dosing device is mainly composed of dry powder storage tank, water ejector, dispensing tank, pressurized water system and control system. During operation, the water ejector is blocked, the dispensing water pressure is unstable, and the pharmaceutical precipitated at the bottom of the dispensing tank blocks the dispensing pipeline, resulting in the dispensing system cannot run normally and the interlocked centrifuge stops running.

 

Countermeasures

1. Reduce the amount of dry powder stored in the powder storage tank, increase the frequency of adding dry powder to the powder storage tank, and avoid the water vapor in the process of conveying dry powder to the water injector to combine with the dry powder in the powder storage tank and then harden, thus blocking the normal operation of the water injector.

 

2. Increase the pipeline booster pump on the fresh water pipe for dispensing the medicine, so that the pipe network pressure is maintained at about 0.5MPa, which is the full mixing of water and dry powder in the water injector to better achieve the concentration of the dispensing agent.

 

3. Regularly clean the deposited liquid at the bottom of the liquid medicine storage tank to ensure the cleanliness of the bottom of the medicine tank and avoid the deposition of debris blocking the drug delivery pipeline.


B - Sampling and analysis of centrifuge mud
The properties of the sludge in the front directly affect the sedimentation effect of the sludge in the thickening tank, the moisture content of the sludge is high, under the same settling time, after entering the centrifuge, in the case of a certain amount of mud, the water content of the sludge after centrifuge treatment will increase correspondingly, and the solid content of the supernatant will also increase, showing a turbidity state.
Countermeasures: Sample and analyze the settled sludge inside the thickening tank regularly, adjust the settling time of the sludge in the thickening tank appropriately according to the water content of the sludge, and ensure the process index of centrifuge sludge.


Conclusion
After the centrifuge operation and debugging stage, it fully mastered the adjustment method of the control factors affecting the operation of the centrifuge, and under the same conditions, it could timely and accurately adjust the control factors to ensure the continuous operation of the centrifuge under certain conditions and achieve the best working state.

 

 

 